Design
Our engineers are senior experts with over 10 years of experience in nano microporous insulation materials. They possess extensive knowledge and expertise. We can provide comprehensive drawing design for your projects, such as in the petrochemical, steel, ceramic, and aluminum industries, as well as various types of heat treatment furnaces, roller kilns, and tunnel kilns.
Why engineering buyers trust Design
Anchor-tech track record
The design service on this page is delivered by the Anchor-tech application engineering team — currently 6 engineers with an average of 8 years of insulation-engineering experience (range 3 to 22 years). The team's background is mixed: 3 engineers with steel-mill or non-ferrous-metal process engineering experience, 2 with petrochemical or marine engineering experience, and 1 with HVAC and building-services experience. All design work is supervised by the lead engineer (Mr. Chen Wei, 22 years' insulation industry experience, formerly with a major European refractory manufacturer) who reviews every design report before issue. The team uses industry-standard calculation methods (ASTM C680 for steady-state heat flow, ASTM C1057 for guarded-hot-plate heat-flow-meter calibration) and finite-element modelling (COMSOL Multiphysics) for complex geometries. We do not outsource design work to third-party engineering firms — every calculation, drawing, and report is produced by our in-house team.
Anchor-tech track record
The five-step engineering workflow on this page is the workflow refined over more than 600 design engagements since 2014. The most common reason a design engagement fails to deliver value is incomplete input data from the customer — typically the host equipment operating temperature profile is missing or the existing insulation specification is unknown. To minimise this risk, our standard inquiry form (available on request) asks for 18 specific data points; customers who submit the inquiry form receive a complete design proposal in the standard 10–15 working day timeline, while customers who submit a free-form inquiry typically take 3–5 additional working days as we exchange clarification emails. Customers who have an active installation with our product and want to upgrade or expand the insulation specification can request a "design refresh" where we re-issue the original design with current data; the refresh fee is 50% of the original design fee, or free if the original order was above 50 m³.
Anchor-tech track record
Design recommendations we issue are engineering opinions, not guarantees of field performance. The thermal-conductivity values used in our calculations are the lot-average values from our heat-flow-meter verification (200 / 400 / 600 / 800 °C); field performance depends on installation quality, operating conditions, and maintenance practice. If a customer implements our design recommendation and the field performance differs from the calculated prediction by more than 15%, we will investigate at no charge and either revise the design or explain the deviation — typically the deviation is from installation factors (gaps in board joints, compression of the board during installation, unexpected operating temperatures). We do not guarantee energy savings in absolute terms; we guarantee that the calculated heat flow is accurate to within the verification tolerance of our thermal-conductivity data. Past design engagements have ranged from 2-piece prototype reviews to 800 m³ petrochemical vessel insulation specifications; design files are archived and available for reference.
Frequently Asked Questions
Quick technical and commercial answers about Design for engineering buyers, procurement teams, and installers. For project-specific questions not covered here, contact our application engineering team.